Installing the Remote Status Indicator
Shortening the cables
01750058390 G
ProCash 2050xe USB - Installation Guide
165
1
3
2
Remove screws (1) and (3) and the
strain relief (2).
Remove the connecting cable.
•
Shorten the connecting cable to the desired length.
•
Shorten the cable end as shown in the following diagram.
60 (23.62")
4.5
(0.18")
You must strip 60 mm (2.36") of the
cable insulation and 4.5 mm (0.18") of
the individual wire insulation. The
individual wire ends must be twisted.
•
Lead the connecting cable through the opening in the lower section and
secure it with the strain relief.
Marking on wires
i
The wires are marked with an adhesive label at the end as follows:
RED
- RED LIGHT
WHITE
- YELLOW LIGHT
GREEN - GREEN LIGHT
BLACK -
GND