PAGE 133 OF 164
PNEUMATIC MAST WITH REMOTE LOCKING SYSTEM
OPERATING INSTRUCTIONS
TP-5580101-A
FEBRUARY 2022
8. If operating the mast from the control box, select “BOX” on the control box. The “BOX/
REMOTE” switch is a maintained switch and will keep its position.
If operating the mast from the HHRC, select “REMOTE” on the control box.
If operating manually (typically an emergency operation when power is not available):
a. Ensure all electrical circuits are de-energized and properly tagged to prevent injury during
operation.
b. Disconnect the air hose at the base of the mast.
c. Connect a hand pump to the base of the mast.
d. Use the hand pump to pressurize the mast.
e. Skip to Step 12.
9. Select “HOLD”. The “HOLD/EXHAUST” switch is a maintained switch and will keep its
position.
10. Select and hold “UP” to extend the mast. The “UP” function on the “UP/DOWN” switch is
momentary. Continue to hold “UP” until the mast is fully extended.
Maintain visual contact throughout extension to avoid overhead obstructions and to ensure
none of the cables become tangled or snag on anything. Do not exceed the maximum
recommended operating pressure of 35 psi at any time.
11. When the mast is fully extended, release the “UP” switch and select “EXHAUST” to exhaust
air from the mast.