PAGE 120 OF 164
PNEUMATIC MAST WITH REMOTE LOCKING SYSTEM
OPERATING INSTRUCTIONS
TP-5580101-A
FEBRUARY 2022
2. Fasten the hose adaptor to the drain hole (Figure 5-29). Apply PTFE Tape to all threaded
joints. Turn the hose adaptor in ONLY 1 ½ to 2 times after initial engagement of the threads.
Turning further will damage the mast. Tighten the locknut to secure the hose adaptor in place.
Overtightening could cause the hose adaptor to contact the moving intermediate tube.
Figure 5-29 Ultra Heavy Duty Drain Kit Installation
3. Drill a hole in the vehicle or enclosure to route the water outside.
4. Fasten the bulkhead fitting (Figure 5-29) to the hole.
5. Attach the polyethylene tube to the hose adaptor and the bulkhead fitting (Figure 5-29). As
necessary, the polyethylene tube may be cut shorter to fit the customer-specific application.
Apply PTFE Tape to all threaded joints.
Washer
Hose Adaptor
Drain Tube
Lock Nut
See View A
View A - Drain Kit (Top)
Drain Tube
Bulkhead Fitting
View B - Drain Kit (Bottom)
Drain Cock
See View B
See View C
View C - Drain Cock
Summary of Contents for 10-60 HDL