6.3.2.1
Partial Extension Applications
This section describes applications using partial extension of the mast assuming the use of a
hold down platform and two hold down leashes (Section 3.3.5). Note that masts with 6.75-inch
base tubes only have and require one hold down leash.
For partial extension applications:
1. Install the hold down platform on top of the mast.
2. Secure a hold down leash to the hold down platform at a lug.
3. Secure a hold down leash to a guy lug on the desired mast collar. The guy lug on the desired
collar should be in-line with the lug on the hold down platform.
4. Secure the second hold down leash to the hold down platform at the lug opposite the first
hold down leash.