EtherNet/IP gateway
Wieland Electric GmbH | BA000970 | 07/2019 [9855]
87
Table 44: Overview of the discrete output point objects (0x09) supported by the SP-COP2-ENI module
Class Instance Attribute Access
Data type
Description
Data range
9
0 = Class
1
Read
UINT
Revision of the class
1
9
0 = Class
2
Read
UINT
Max. instance
400
9
0 = Class
3
Read
UINT
Number of instances
400
9
0 = Class
6
Read
UINT
Max. class attribute ID
7
9
0 = Class
7
Read
UINT
Max. instance attribute ID
6
9
1 to 400
1
Read
USINT
Number of attributes
5
9
1 to 400
2
Read
USINT[5]
List of support attributes
{1, 2, 3, 5, 6}
9
1 to 400
3
Write,
read
BOOL
The value of the logic output bit, which
is configured by the
intput data blocks
1 to 5
in samosPLAN
6, stands for the
data transferred by the PLC to the logic
of the controller module.
0 = Off,
1 = On
9
1 to 400
5
Write,
read
BOOL
Error action (specified value on loss of
connection to the PLC)
0 = Interfe-
rence value,
1 = Last state
9
1 to 400
6
Write,
read
BOOL
Interference value
0 = Off, 1 = On
Discrete Input Group Object
80068491
The discrete input group objects are part of the device profile
Discrete universal I/O device.
The object of class 29 plays a role with regard to the alarm bit. It collects the process alarms of all
the input terminals of the SP-COP2-ENI module as well as the safe input/output expansion modules
in one bit. If an error occurs at at least one input terminal and the SP-COP2-ENI module is in
Run
mode, the value of the attribute 5 of instance 1 equals 1. In all other cases, the value equals 0.
Table 45: Overview of the discrete input group object (0x1D) supported by the SP-COP2-ENI module
Class Instance
Attribute Access
Data type
Description
Data range
29
0 = Class
1
Read
UINT
Revision of the class
1
29
0 = Class
2
Read
UINT
Max. instance
1
29
0 = Class
3
Read
UINT
Number of instances
1
29
0 = Class
6
Read
UINT
Max. class attribute ID
7
29
0 = Class
7
Read
UINT
Max. instance attribute ID
5
29
1
1
Read
USINT
Number of attributes
5
29
1
2
Read
USINT[5]
List of support attributes
{1, 2, 3, 4, 5}
29
1
5
Read
BOOL
Group state of all input terminals (state
of instances 401 to 420 of class 8)
0 = No error,
1 = Error
Discrete Output Group Object
80094091
The discrete output group objects are part of the device profile
Discrete universal I/O device.
The object of class 30 plays a role with regard to the alarm bit. It collects the process alarms of all
the output terminals of a SP-COP2-ENI or SP-SDIO module in one bit. If an error occurs at at least
one output terminal and the SP-COP2-ENI module is in
Run
mode, the value of the attribute 5 of in-
stance 1 equals 1. If the SP-COP2-ENI module is in
Critical error
mode, the attribute value is also 1.
In all other cases, the value equals 0.
8.4.5
8.4.6