PROFIBUS DP gateway
Wieland Electric GmbH | BA000970 | 07/2019 [9855]
113
The content of the data blocks can be freely selected, but has been preconfigured as follows in the
samosPLAN
6:
Table 77: Predefined content of input data block 1–5 of the SP-PROFIBUS-DP module
Data block 1
Data block 2
Data block 3
Data block 4
Data block 5
Output data block Output data block Output data block Output data block Output data block
Byte 0
Input values for
Module 0 (I1..I8)
Input values for
Module 1
Output values for
Module 1
Not allocated
Not allocated
Byte 1
Input values for
Module 0 (I9..I16)
Input values for
Module 2
Output values for
Module 2
Not allocated
Not allocated
Byte 2
Input values for
Module 0 (IQ1..IQ4)
Input values for
Module 3
Output values for
Module 3
Not allocated
Not available
Byte 3
Output values for
Module 0
(Q1..Q4,IQ1-IQ4)
Input values for
Module 4
Output values for
Module 4
Not allocated
Byte 4
Direct data
(Off) 0
Input values for
Module 5
Output values for
Module 5
Not allocated
Byte 5
Direct data
(Off) 1
Input values for
Module 6
Output values for
Module 6
Not allocated
Byte 6
Direct data
(Off) 2
Input values for
Module 7
Output values for
Module 7
Not allocated
Byte 7
Direct data
(Off) 3
Input values for
Module 8
Output values for
Module 8
Not allocated
Byte 8
Direct data
(Off) 4
Input values for
Module 9
Output values for
Module 9
Not allocated
Byte 9
Direct data
(Off) 5
Input values for
Module 10
Output values for
Module 10
Not allocated
Byte 10
Direct data
(Off) 6
Input values for
Module 11
Output values for
Module 11
Not allocated
Byte 11
Direct data
(Off) 7
Input values for
Module 12
Output values for
Module 12
Not allocated
Length
12 bytes
12 bytes
12 bytes
12 bytes
2 bytes
Start
address
1
13
25
37
49
Detailed information about the content of the process diagram may be found here:
to the network (network input data sets [ch. 3.2, p. 19]
Delete any bytes not required
You can delete bytes pre-allocated by samosPLAN
6 that you do not require by clicking on them with
the mouse.
Launch samosPLAN
6.
Read in the hardware configuration, including the PROFIBUS-DP gateway.
Instructions: Software manual, chapter "Connecting to the safety controller"
Switch to the
Gateway
view.
Click on the byte you do not need and wish to delete.
Click on the
Delete
icon in the command bar.
You will find further information about how to configure the process diagram here: