Centurion Water Heater- Edge [ii]: Install-Operation-Service
FOREWORD
OMM-0153_A
• 8/25/2022 Technical Support • (800) 526-0288 • Mon-Fri, 8 am - 5 pm EST Page 5 of 131
FOREWORD
The
PVI CENTURION
natural gas fueled modulating and condensing water heater represents a
true industry advance to meet the needs of today's energy and environmental concerns.
Designed for application in any closed loop hydronic system, the CENTURION's modulating
capability relates energy input directly to fluctuating system loads. CENTURION models provide
extremely high efficiency operation and are ideally suited for modern low temperature, as well
as conventional, water heating systems.
The CENTURION models operate within the following input and output ranges:
CENTURION Water Heater Intake and Output Ranges
MODEL
INPUT RANGE (BTU/HR.)
OUTPUT RANGE (BTU/HR.)
MINIMUM
MAXIMUM
MINIMUM
MAXIMUM
CEN2000
100,000 (29.3 kW)
2,000,000 (586 kW)
98,000 (28.7 kW)
1,920,000 (563 kW)
The output of CENTURION Water Heaters
is a function of the unit’s firing rate (valve position)
and return water temperature.
When installed and operated in accordance with this Instruction Manual, the
CENTURION 2000
complies with the NOx emission standards outlined in:
South Coast Air Quality Management
District (SCAQMD), Rule 1146.2
.
Whether used in singular or modular arrangements, CENTURION Water Heaters offer the
maximum venting flexibility with minimum installation space requirements. CENTURION Water
Heaters are Category II and IV, positive pressure appliances. Single and/or multiple breeched
units are capable of operation in the following vent configurations:
•
Room Combustion Air:
o
Vertical Discharge
o
Horizontal Discharge
•
Ducted Combustion Air:
o
Vertical Discharge
o
Horizontal Discharge
The vent for this appliance shall not terminate:
1. Over public walkways; or
2. Near soffit vents or crawl space vents or other areas where condensate or vapor could
create a nuisance or hazard or cause property damage; or
3. Where condensate vapor could cause damage or could be detrimental to the operation
of regulators, relief valves, or other equipment.
See CSA/ANSI Z21.10.3:19, Figure 2-A and 2-B for vent terminal clearances.
CENTURION Water Heaters are capable of being vented utilizing PVC, CPVC, Polypropylene
and AL29-4C vent systems.
The advanced electronics in CENTURION Water heaters are available in several selectable
modes of operation offering the most efficient operating methods and energy management
system integration.