![WATANABE WPMZ-1 Instruction Manual Download Page 75](http://html1.mh-extra.com/html/watanabe/wpmz-1/wpmz-1_instruction-manual_3499830075.webp)
Graphical Digital Panel Meter WPMZ-1 INSTRUCTION MANUAL
74
IM-0882-03
【
RS-485
Modbus
】
Communication
protocol
: Modbus RTU
Synchronization
method
: Asynchronous
Communication
method
: 2-wire half- duplex
Baud rate
: 9600bps,19200bps,38400bps
Data length
: 8bit
Start bit
: 1bit
Parity bit
: None, Odd, Even
Stop bit
: 1bit
Used signal names : Non-inverting (+), Inverting (-)
Number of
connectable units
: 31
Cable length
: Max.1.2km
(
total
)
*Conforming CE mark, less than 30m