Graphical Digital Panel Meter WPMZ-1 INSTRUCTION MANUAL
40
IM-0882-03
10.
OUTPUT ADVANCED SETTING
Here, the items of output setting which are not explained in the “BASIC SETTING” are explained.
Since the output options differ depending on the model, the items that can be set change depending on the model.
The correspondence between model number and output option is as follows.
・
WPMZ-1-□□□-X□-□□□: No output
・
WPMZ-1-□□□-1□-□□□:
Analog output
・
WPMZ-1-□□□-2□-□□□:
BCD output(open collector NPN)
・
WPMZ-1-□□□-3□-□□□:
BCD output(open collector PNP)
・
WPMZ-1-□□□-4□-□□□:
RS-232C
・
WPMZ-1-□□□-5□-□□□:
RS-485(Modbus RTU)
Compare List settings
When you move on to “Compare List” screen, the comparison output setting parameters are displayed in a list.
In the example of the red frame in the upper left of the figure below (AL1 setting), [AL1 / OutputDispValue: Ach /
OnConditions: Excess] and [Threshold: +1234.5].
In addition, in the case of “LevelJudge” and “ZoneJudge”, “Threshold” can be changed.
*In the case of change “DiffJudge”, “Threshold” is not displayed.
*By registering this screen with a shortcut key, you can move on to this screen directly from measurement
display.
Operation:[MENU]
⇒
[Output]
⇒
[CompareList]
CompareAL1~4
ActCondition
Select the condition of comparison output function.
Operation:[MENU]
⇒
[Output]
⇒
[CompareAL1], [CompareAL2], [CompareAL3], [CompareAL4]
⇒
[ActCondition]
Setting value: Always(Default)
ExceptNearZero *
OnStable *
OnStableExceptNearZero*
OnHold
*Please also set “ZeroArea”, “StableArea”, “StableTime” of input setting.
*In the case of judgment of the calculation result, it is judged whether both Ach and Bch satisfy the condition,
not the condition judgment based on the calculation result.