![WATANABE WPMZ-1 Instruction Manual Download Page 12](http://html1.mh-extra.com/html/watanabe/wpmz-1/wpmz-1_instruction-manual_3499830012.webp)
Graphical Digital Panel Meter WPMZ-1 INSTRUCTION MANUAL
11
IM-0882-03
5.
CONNECTING TERMINALS
WIRING TO TERMINALS
The connections to this product are done by connecting wires to the screw terminal block (power
supply) and screwless terminal blocks on the back side of the body. Show below for the method and
precautions.
CONNECTING TERMINALS
Use crimp-type terminal lugs for M3 screws to connect the terminals.
①
Loosen the screws of the terminal block.
In the case of R-type terminal lugs, remove the screw terminals
from the terminal block.
②
Insert lugs under the washers of loosened screws and fasten the screws.
(
Recommended torque:0.6 [N
・
m]
)
WIRING TO SCREWLESS TERMINALS
①
Pushing the wire release button with a flat-blade screwdriver, open the wire insert hole.
(Flat-blade screwdriver : The point of a blade width 2.5mm)
②
Wire is inserted in an expanded wire insertion hole and a flat-blade screwdriver is removed.
(
Suitable wire:AWG24 to 16
)
THE LOCATION OF EACH TERMINAL STAND
Note: In this manual, “channel A”, “channel B” may be abbreviated to “chA”,”chB” (or “Ach”,”Bch”).
5.8max.
Suitable crimping
terminal
5.8max.
Wire insert hole
Wire release button
Ach inputs
Bch inputs
Power
Comparative output/External control input
outputs
UPPER ROW TERMINALS
MIDDLE ROW
TERMINALS
LOWER ROW TERMINALS