ENGLISH
Name
Terminals
Connection
TRPS (LOBBY MAC2 and
QUATTRO)
15
Agnd*
UI2*
Supply air pressure transmitter (see section VI.6)
TRPS (LOBBY MAC2 and
QUATTRO)
16
Agnd*
UI3*
Return air pressure transmitter (see section VI.6)
CO2 (DIVA and QUATTRO)
17
Agnd*
UI4*
CO2
transmitter (see section VI.7)
THS/THA or K1 auxiliary for
PREMIUM and INFINITE BE only
18
19
BC:
On the
VORT NRG EC PREMIUM BC
and
VORT NRG EC INFINITE BC
versions, the
THA
is factory-wired.
On the
VORT NRG EC FIRST
versions, if you install a
BC
module in
addition to the
VORT NRG EC
unit, it must be connected to terminals C
and 2 of the anti-frost thermostat.
BE:
On the
VORT NRG EC PREMIUM BE
and
VORT NRG EC INFINITE BE
versions, the auxiliary contact K1 is factory-wired.
On the VORT NRG EC FIRST
version, if you install an additional
BE
module, it must be connected to terminals C and 2 of the coil safety
thermostat.
BC/BE
20
21
22
BC:
To be connected to the 3-way valve of the hot water coil (see section VI.11)
Non-integrated
BE (VORT NRG EC FIRST):
(see section VI.14)
Integrated BE (VORT NRG EC PREMIUM BE, VORT NRG EC INFINITE BE):
(see section VI.15)
BIM
23
24
25
To be connected to the motorised bypass servomotor (see section VI.8)
BF
26
27
28
To be connected to the 3-way valve of the cold water coil (see section VI.11)
* direct connection to CORRIGO
VI.4.3 Bridging in case of unused option.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
Name
Terminals
Connection
ADP
5-6
If you do not use the remote
firefighter stop function, terminals
5 and 6 should be bridged. This is
done in factory.
THS/THA
18-19
For
VORT NRG EC FIRST
only,
terminals 18 and 9 should be
bridged if you are not adding a
coil in the duct.
This is done in factory.
16
Summary of Contents for VORT NRG EC 3000
Page 37: ...X NOTES GRAPHS AND COMMUNICATION DIAGRAMS ENGLISH Date Observations 37...
Page 39: ...ENGLISH REPEATER RS485 100 metres Maximum 6 control units MASTER Ext Disp REPEATER 39...
Page 40: ...ENGLISH BMS LON 100 metres MASTER Ext Disp LON EXTENSION OU 40...
Page 54: ...54 NOTE ENGLISH...
Page 84: ...X REMARQUES GRAPHIQUES ET DIAGRAMMES DE COMMUNICATION 84 FRAN AIS Date Observations...
Page 86: ...FRAN AIS R P TEUR RS485 100 m tres Maximum 6 centrales MA TRE Ext Disp R P TEUR 86...
Page 87: ...FRAN AIS BMS LON 100 m tres MASTER Ext Disp EXTENSION LON OU 87...
Page 101: ...101 IX NOTE FRAN AIS...
Page 131: ...X NOTIZEN SCHAUBILDER UND KOMMUNIKATIONSDIAGRAMME DEUTSCH Datum Anmerkungen 131...
Page 134: ...DEUTSCH BMS LON 100 Meter MASTER Ext Disp ERWEITERUNG LON OU 134...
Page 148: ...148 IX NOTE DEUTSCH...