3-34
CO/PBX Connections
Chapter 3 - System Installation
7. Push the DTRU4 module onto these connectors to seat it securely.
Figure 3-19: PRIB w/DTRU4 Module Installation
The PRIB is offered as a stand-alone card or as a kit which includes the PRIB, CSU, and cables.
Basic Rate Interface Board
The Basic Rate Interface Board (BRIB) interface provides four Basic Rate Interface circuits. Each
circuit is comprised of two bearer (64Kbps each) and one data (16Kbps) channels (2B+D).
When a BRIB is programmed into the
XTS
system, the system interprets all B channels as
trunks. Thus, one BRIB which contains four 2B+D circuits provides eight line appearances to
the
XTS
system.
The BRIB uses the U interface of the BRI standard. Connection to the network is made via RJ45
connectors on the front edge of the board. No CSU device is required to connect to the
central office. The BRIB card uses eight time slots when installed.
Table 3-15: BRIB Ordering Information
BRIB Ordering Information
Ordering Code
Capability P
National ISDN
NI-1
DT
RU
4
DT
RU
4
CN2
CN1
CN19
CN18
CN16
CN2
CN1
CN17
Summary of Contents for STARPLUS Triad XTS
Page 1: ...STARPLUSTM Triad XTS Installation...
Page 10: ...N O T E S...
Page 20: ...1 12 Product Description Chapter 1 Introduction...
Page 22: ...N O T E S...
Page 36: ...N O T E S...
Page 42: ...3 8 KSU Installation Chapter 3 System Installation Figure 3 4 Mounting Cabinets 0 1 2 48 3...
Page 77: ...CO PBX Connections 3 43 Chapter 3 System Installation Figure 3 25 Case 2 of Clock Chain...
Page 79: ...CO PBX Connections 3 45 Chapter 3 System Installation Figure 3 27 Case 4 of Clock Chain...
Page 104: ...N O T E S...
Page 134: ...4 32 VOIP Maintenance and Troubleshooting Chapter 4 Maintenance and Troubleshooting...
Page 138: ...iv Index...