System Configuration Tables
2-11
Chapter 2 - System Specifications
Table 2-12: Single Line Audible Signals
Type of Signal
Frequency
Signal Duration
(in seconds unless otherwise indicated)
Single Line Signals
Incoming CO Line
20Hz 90 VAC
2.0 on/4.0 off; Repeated
Intercom Tone Ringing
20Hz 90 VAC
1.0 on/0.2 off/1.0 on/4.0 off; Repeated
Transferred CO Line
20Hz 90 VAC
1.0 on/0.2 off/1.0 on/4.0 off; Repeated
CO Line Recall
20Hz 90 VAC
2.0 on/4.0 off; Repeated
CO Queue Call Back
20Hz 90 VAC
1.0 on/2.0 off; Repeated
Type of Signal
Frequency
Signal Duration
(in seconds unless otherwise indicated)
Single Line Confidence Tones
Intercom Ringback
440+480
1.0 on/3.0 off
Transferred CO Line
440+480
1.0 on/0.2 off/1.0 on/4.0 off
Call Announce
440
0.2 on/0.2 off; (3 bursts)
Busy Tone
480+620
1.0 on/0.2 off/1.0 on/0.2 off/0.2 on/ 0.2 off/0.2on/
0.2 off/0.2 on; Repeated
Error Tone
480+620
0.2 on/0.1 off; Repeated
Intercom Dial Tone
350+440
Steady
DND Tone
350+440
0.2 on/0.2 off/0.2 on/0.2 off/0.2 on/0.2 off; burst
Paging Confirmation Tone
350+440
1.0 on
Conference Time-out Tone
440
Programmable Steady Tone
Confirmation Tone
350+440
0.2 on/0.2 off; (3 bursts)
Summary of Contents for STARPLUS Triad XTS
Page 1: ...STARPLUSTM Triad XTS Installation...
Page 10: ...N O T E S...
Page 20: ...1 12 Product Description Chapter 1 Introduction...
Page 22: ...N O T E S...
Page 36: ...N O T E S...
Page 42: ...3 8 KSU Installation Chapter 3 System Installation Figure 3 4 Mounting Cabinets 0 1 2 48 3...
Page 77: ...CO PBX Connections 3 43 Chapter 3 System Installation Figure 3 25 Case 2 of Clock Chain...
Page 79: ...CO PBX Connections 3 45 Chapter 3 System Installation Figure 3 27 Case 4 of Clock Chain...
Page 104: ...N O T E S...
Page 134: ...4 32 VOIP Maintenance and Troubleshooting Chapter 4 Maintenance and Troubleshooting...
Page 138: ...iv Index...