3-40
CO/PBX Connections
Chapter 3 - System Installation
The clock cable should be connected to the OUT position on the connector on the PRIB1. The
clock cable should be connected to the IN position on PRIB2. SW2 of the PRIB1 and PRIB2
should be placed in the ON position. The three T1IBs are not connected with the clock control
cable and SW3 on these boards should be in the OFF position.
(3) T1IBs and (2) PRIBs
The clock cable should be connected to the OUT position on the cable connector on the T1IB
and connected to the IN position on the connector on the T1IB2.
The clock cable should be connected to the OUT position on T1IB2 and connected to the IN
position on the T1IB3. SW3 of T1IB1 should be placed in the ON position, with SW3 on T1IB2
and T1IB3 being OFF. The two PRIBs are not connected with clock control cables, and SW2 on
the PRIBs should be in the OFF position.
(3) PRIBs and (2) BRIBs
The clock cable should be connected from the OUT position of the PRIB1 to the IN connectors
of all the cards and all clock switches should be in the ON position.
T1IB1
T1IB2
T1IB3
PRIB1
PRIB2
SW3 On
SW3 Off
SW3 Off
SW2 Off
SW2 Off
PRIB1
PRIB2
PRIB3
BRIB1
BRIB2
SW2 On
SW2 On
SW2 On Switch 4, SW2 On Switch 4, SW2 On
Summary of Contents for STARPLUS Triad XTS
Page 1: ...STARPLUSTM Triad XTS Installation...
Page 10: ...N O T E S...
Page 20: ...1 12 Product Description Chapter 1 Introduction...
Page 22: ...N O T E S...
Page 36: ...N O T E S...
Page 42: ...3 8 KSU Installation Chapter 3 System Installation Figure 3 4 Mounting Cabinets 0 1 2 48 3...
Page 77: ...CO PBX Connections 3 43 Chapter 3 System Installation Figure 3 25 Case 2 of Clock Chain...
Page 79: ...CO PBX Connections 3 45 Chapter 3 System Installation Figure 3 27 Case 4 of Clock Chain...
Page 104: ...N O T E S...
Page 134: ...4 32 VOIP Maintenance and Troubleshooting Chapter 4 Maintenance and Troubleshooting...
Page 138: ...iv Index...