Maintenance Access
4-13
Chapter 4 - Maintenance and Troubleshooting
System Configuration
This illustratration shows the configuration of the
XTS
System when the installer types
d<space>s
at the
maint
> prompt.
Figure 4-2: Remote Maintenance - System Configuration
CAB
Shows the cabinet number for each board installed.
SLOT
Shows the slot position where each board is installed.
CARD
Identifies the type of board.
CKTS
Identifies the amount of circuits associated with the board.
SERV STAT
Out-of-Service
(OOS)
status can indicate the entire card is out of service, or a
specific station is not installed or installed but not operational.
In-Service (
INS)
status can indicate a specific station is installed and operating
correctly.
BRD OPTS Lists any optional boards being used by the system.
FW VER.
Identifies the firmware version of each board.
maint>d s
CAB/SLOT CARD CKTS SERV STAT BRD OPTS FW VER.
--------- ---- ---- ----------- ---------- ---------
0 0 DT24 24 INS 0 00-0
0 1 DTIB 12 INS 0 00-0
0 2 T1IB 24 INS 0 10F-0
0 3 PRIB 24 OOS 0 10C-0
0 4 SLIB 6 INS 0 00-0
0 5 LCOB 6 INS 0 00-0
0 6 LCOB 6 INS 0 00-0
0 7 DIDB 4 INS 0 00-0
0 9 MPB 0 INS V300 Eng. Vx.xx Pxx
Station Count 42 Coline Count 63
maint>
Summary of Contents for STARPLUS Triad XTS
Page 1: ...STARPLUSTM Triad XTS Installation...
Page 10: ...N O T E S...
Page 20: ...1 12 Product Description Chapter 1 Introduction...
Page 22: ...N O T E S...
Page 36: ...N O T E S...
Page 42: ...3 8 KSU Installation Chapter 3 System Installation Figure 3 4 Mounting Cabinets 0 1 2 48 3...
Page 77: ...CO PBX Connections 3 43 Chapter 3 System Installation Figure 3 25 Case 2 of Clock Chain...
Page 79: ...CO PBX Connections 3 45 Chapter 3 System Installation Figure 3 27 Case 4 of Clock Chain...
Page 104: ...N O T E S...
Page 134: ...4 32 VOIP Maintenance and Troubleshooting Chapter 4 Maintenance and Troubleshooting...
Page 138: ...iv Index...