3-64
Wall Mounting the Electronic Key Telephone
Chapter 3 - System Installation
Power Failure Transfer Unit Wiring
The Power Failure Transfer Unit (PFTU) is wired from the 25-pair connector to the MDF, cross
connected to the CO Line inputs from the telephone company, to the CO Line inputs of the
system, and to Power Failure SLTs. The basic connections are shown in
Figure 3-40
and the
connector configuration is given in
Table 3-19
. Note that the SLT may also be connected to a
SLIB as shown in the figure.
Figure 3-40: PFTU Wiring
Wall Mounting the Electronic Key Telephone
All connections to the Electronic Key Telephone are fully modular. To wall mount the
Electronic Key Telephone, it is necessary to have one Wall Mount Kit and one standard-type
jack assembly designed for normal wall hanging applications.
1. Unplug the line cord from the phone. This line cord is not be required and should be
retained as a maintenance replacement item.
2. Lift the plastic number retainer upward and expose the screw underneath. Remove the
screw and the handset tab. Replace it with the handset tab from the Wall Mount Kit.
3. Be careful to position the tab so that the protrusion faces the hookswitch. This allows the
handset to remain secure when the telephone is on the wall. Replace the screw and snap
the number retainer into place.
4. Substitute the short modular cord from the Wall Mount Assembly into the modular
connector vacated by the line cord.
5. Align the wall mount baseplate with holes on the bottom of the telephone. Snap in place.
6. Now match the two key hole slots on the baseplate with the lugs on the 630-A type jack.
Align the modular connector and slide telephone into place. Refer to
Figure 3-41
.
MDF (PFTU)
COR1-IN
COT1-IN
COR1-OUT
COT1-OUT
TEL1-R
TEL1-T
SLIB1-R
SLIB1-T
CO L1
CO L2
LCOBE
SLT
SLIBE
Subscriber
OR/WH
WH/BL
BL/WH
BN/WH
WH/BN
WH/GN
GN/WH
WH/OR
Summary of Contents for STARPLUS Triad XTS
Page 1: ...STARPLUSTM Triad XTS Installation...
Page 10: ...N O T E S...
Page 20: ...1 12 Product Description Chapter 1 Introduction...
Page 22: ...N O T E S...
Page 36: ...N O T E S...
Page 42: ...3 8 KSU Installation Chapter 3 System Installation Figure 3 4 Mounting Cabinets 0 1 2 48 3...
Page 77: ...CO PBX Connections 3 43 Chapter 3 System Installation Figure 3 25 Case 2 of Clock Chain...
Page 79: ...CO PBX Connections 3 45 Chapter 3 System Installation Figure 3 27 Case 4 of Clock Chain...
Page 104: ...N O T E S...
Page 134: ...4 32 VOIP Maintenance and Troubleshooting Chapter 4 Maintenance and Troubleshooting...
Page 138: ...iv Index...