Additional information
109
System components
(continued)
Remote control
(continued)
D
Printed Circuit Board DIP switches
(rear of the top casing)
Remote control
affects
DIP switch
setting
System circuit A1
(Heating circuit
selection
button
!
)
Factory setting
Mixing valve
circuit M2
(Heating circuit
selection
button
?
)
Mixing valve
circuit M3
(Heating circuit
selection
button
§
)
When connecting a separate room
temperature sensor, set DIP
switch S30.3 to ON.
Specification
Power supply via 145 KM BUS.
Safety class:
III
Protection:
IP 30
Permiss. ambient
temperature
In use:
0 to +40°C
32 to 104°F
In storage and transport:
–20 to +65°C
–4 to +149°F
Setting range for
Normal set room temp:
10 to 30°C;
50 to +86°F
adjustable between
3 to 23°C
37 to 73°C
or
17 to 37°C
63 to 97°F
via coding address E1
Reduced set room temp:
3 to 37°C
37 to 97°F
Battery type:
Use alkaline
manganese
batteries
type MICRO-
LR03 (AAA) which
do not contain
pollutants
5285
941
-
0
1
D
S30