12
3
4
ON
70
Components
Remote control
(cont.)
A
PCB DIP switches
(back of the casing top)
Remote control
affects
DIP switch
setting
Heating circuit
without mixer
A1
(Heating circuit
selection key
!
)
As delivered
condition
12
3
4
ON
Mixer circuit M2
(Heating circuit
selection key
?
)
12
3
4
ON
When connecting a separate room
temperature sensor, set DIP switch
S3.3 to ON.
Specification
Power supply via KM BUS.
Safety class:
III
Protection level
IP 30
Permiss. ambient
temperature
H
in operation:
0 to + 40
º
C
H
during storage
and transport:
20 to + 65
º
C
Setting range for
set standard
room temp.:
10 to 30
º
C;
adjustable from
3 to 23
º
C
or
17 to 37
º
C
via coding
address E1
reduced set
room temp.:
3 to 37
º
C
5862700GB
A
12
3
4
ON
S3
3 2 1
RTS
int. ext.
12
3
4
S3