14
Installation
Changing the control thermostat setting
(if required)
Adjustment to 87
º
C/95
º
C
The control thermostat is supplied with a factory setting of 75
º
C.
Note
Do not set the control thermostat above 75
º
C if the high limit safety cut−out
has been adjusted to 100
º
C.
1.
Lever out and remove rotary
selector
R
.
2.
Using a pair of pointed pliers,
break off the cams between 75
and 90 or 95 from the stop disc, as
shown in the drawing.
3.
Fit rotary selector
R
so that the
mark lies between 75 and 90 or 95.
Turn rotary selector
R
fully
clockwise to the end stop.
!
Please note
Excessive DHW temperatures
can damage the DHW cylinder.
If the system is operated in
conjunction with a DHW
cylinder, ensure that the
maximum permissible DHW
temperature is not exceeded.
If necessary, install suitable
safety equipment for this
purpose.
5862700GB
3.
2.
1.