112
Settings and equipment
Settings and equipment
(cont.)
Function in the delivered condition
Modified function
Heating circuit pumps
In the
Heating and DHW
program,
the heating circuit pumps are
switched OFF, when the outside
temperature exceeds the set room
temperature by more than 1K.
In the
DHW only
program,
H
the heating circuit pumps are
only started when there is a risk
of frost,
H
any connected mixer stays closed
(when there is a risk of frost, it
changes to control mode).
j
Heating circuit pump for heating
circuit 1 remains ON
j
Heating circuit pump for heating
circuit 2 remains ON
j
Heating circuit pumps are switched
OFF before the set room
temperature is achieved
j
Heating circuit pump for heating
circuit 1 or 2 are switched subject to
coding address b5
j
Heating circuit pump for heating
circuit 2 is switched OFF, if the mixer
was closed longer than 12min
Heating circuit 1
without mixer
Heating mode/reduced mode
weather−compensated
j
Heating mode: weather−compensated,
red. mode:
with room temperature
hook−up
j
Heating mode: with room temperature
hook−up,
red. mode:
weather−compensated
j
Heating mode/
red. mode:
with room temperature
hook−up
Heating circuit 2
with mixer
Heating mode/reduced mode
weather−compensated
j
Heating mode: weather−compensated,
red. mode:
with room
temperature hook−up
j
Heating mode: with room
temperature hook−up,
red. mode:
weather−compensated
j
Heating mode/
red. mode:
with room
temperature hook−up
5862700GB