77
Components
Vitoair draught stabiliser,
part no. 7338 725 and 7339 703
A
To the burner
B
To the control unit
Colour coding to DIN IEC60757
BK
black
GN/YE
green/yellow
Function check
Press the motor rotary selector and
turn to the central position.
H
Enable burner from control unit
→
The rotary selector should move
towards
3
.
H
Burner OFF
→
The rotary selector should move
towards
5
.
In emergency mode
Press the rotary selector on the
motor and turn clockwise to the limit
stop beyond position
3
.