Stop Codes
224
© 1995-2005 Vibration Research Corporation. All rights reserved.
7.2.22 Test Parameters Changed
Test Parameters Changed (
System Check Stop Code
)
This code indicates that the output was turned off because a critical test parameter such as the
sampling rate was changed. Press the "Auto" button to resume the test.
7.2.23 Watchdog Timeout
Watchdog Timeout (
System Check Stop Code
)
This code indicates that the communications link between the
VibrationVIEW
program and the Signal
Processing hardware was lost. Under normal operations this should never happen. Click the "Run"
button to reset the timeout.
The most likely cause of this error is a loss of power to the
VibrationVIEW
I/O unit.
Other events that could cause this to happen:
·
The
VibrationVIEW
I/O unit is turned on after the program is started.
·
The Ethernet cable connecting the computer with the
VibrationVIEW
I/O unit comes loose.
·
The computer freezes.
·
The computer crashes.
7.3
Sine Stop Codes
7.3.1
Changing Level
Changing Level (
Sine Stop Code
)
This code indicates that the test has finished one level and is starting another. The test continues to
run.
7.3.2
End of Cycle Count Test
End of Cycle Count Test (
Sine Stop Code
)
This code indicates that the test was run for the scheduled number of sine wave cycles (as defined in
the
dialog box). When this code is displayed, the test is complete and the output is
turned off.
7.3.3
End of Sweep Test
End of Sweep Test (
Sine Stop Code
)
This code indicates that the test was run for the scheduled number of frequency sweeps (as defined in
the
dialog box). When this code is displayed, the test is complete and the output is
turned off.
7.3.4
Front Panel Stop
Front Panel Stop (
Sine Stop Code
)
This code indicates that the test was stopped using the "Stop" switch on the front panel of the
VibrationVIEW
I/O unit. When this code is displayed, the test is complete and the output is turned off.
286
286
Summary of Contents for VibrationVIEW
Page 15: ...Document Revision Part I ...
Page 17: ...How To Part II ...
Page 96: ...Menu commands Part III ...
Page 142: ...Test Definition Part IV ...
Page 217: ...Control Centers Part V ...
Page 227: ...Accelerometer Toolbars Part VI ...
Page 231: ...Stop Codes Part VII ...
Page 263: ...Typical Views Part VIII ...
Page 268: ...VibrationVIEW Help 255 1995 2005 Vibration Research Corporation All rights reserved ...
Page 269: ...Dialog Boxes Part IX ...
Page 303: ...Windows Elements Part X ...
Page 309: ...APPENDIX Part XI ...
Page 311: ...APPENDIX 298 1995 2005 Vibration Research Corporation All rights reserved ...