7.3.25 Stop Button Pressed
Stop Button Pressed (
Sine Stop Code
)
This code indicates that the test was halted through operator control, by selecting the
menu command, clicking the "Stop" button on the
or clicking the "Stop"
button in the
.
7.3.26 Waiting for box
Waiting for box n (
Sine Stop Code
)
This code indicates that more than one control box is defined and the system is waiting for all the
boxes to reach the ready state.
If you have a single control box system (4 channels or fewer), select the
menu command and remove any boxes assigned to higher channels.
7.3.27 Channel N Minus Abort
Channel n Minus Abort (
Sine Stop Code
)
This code indicates that the measured acceleration has exceeded the minus abort lines set for channel
n in the
dialog box.
Typically, this results from an accelerometer or cable being loose or from the controller having difficulty
controlling the system as the output sweeps through a resonance frequency.
If the problem is with the controller parameters, see the section
"
How to tune Sine controller parameters
" for information on how to improve the control.
7.3.28 Channel N Plus Abort
Channel n Plus Abort (
Sine Stop Code
)
This code indicates that the measured acceleration has exceeded the plus abort lines set for channel n
in the
dialog box.
Typically, this results from an accelerometer or cable being loose or from the controller having difficulty
controlling the system as the output sweeps through a resonance frequency.
If the problem is with the controller parameters, see the section
"
How to tune Sine controller parameters
" for information on how to improve the control.
7.3.29 Control Minus Abort
Control Minus Abort (
Sine Stop Code
)
This code indicates that the measured acceleration has exceeded the minus abort lines set for the test
in the
dialog box.
Typically, this results from an accelerometer or cable being loose or from the controller having difficulty
controlling the system as the output sweeps through a resonance frequency.
If the problem is with the controller parameters, see the section
"
How to tune Sine controller parameters
" for information on how to improve the control.
112
293
206
104
138
31
138
31
138
31
Summary of Contents for VibrationVIEW
Page 15: ...Document Revision Part I ...
Page 17: ...How To Part II ...
Page 96: ...Menu commands Part III ...
Page 142: ...Test Definition Part IV ...
Page 217: ...Control Centers Part V ...
Page 227: ...Accelerometer Toolbars Part VI ...
Page 231: ...Stop Codes Part VII ...
Page 263: ...Typical Views Part VIII ...
Page 268: ...VibrationVIEW Help 255 1995 2005 Vibration Research Corporation All rights reserved ...
Page 269: ...Dialog Boxes Part IX ...
Page 303: ...Windows Elements Part X ...
Page 309: ...APPENDIX Part XI ...
Page 311: ...APPENDIX 298 1995 2005 Vibration Research Corporation All rights reserved ...