
3-7
3
Setup Mode Organization
Setup Mode Programming Table
STEP
Sensor Location
STEP
Category (Annular Space/Dispenser Pan/Monitor Well/STP Sump/Piping Sump/Other)
FUNCTION
2-WIRE CL SENSOR SETUP
STEP
Sensor Config. - Module 1 (up to 8)
STEP
Sensor Location
STEP
Sensor Types (Discrim. Interstitial/Ultra 2)
STEP
Category (Annular Space/Dispenser Pan/Monitor Well/STP Sump/Piping Sump/Other)
FUNCTION
3-WIRE CL SENSOR SETUP
STEP
Sensor Config. - Module 1 (up to 8)
STEP
Sensor Location
STEP
Sensor Mode (Standard/High Vapor)
STEP
Category (Annular Space/Dispenser Pan/Monitor Well/STP Sump/Piping Sump/Other)
FUNCTION
EXTERNAL INPUT SETUP
STEP
Input Config. - Module 1 (up to 8)
STEP
Input Name
STEP
External Input Type (Standard [NO/NC]/Generator [Select Orientation (NO/NC)/Generator
Tank [All Tanks/By Tank]/Pump Sense [Select Orientation (NO/NC)/Select Tank (Tank #/
None)/Dispense Mode)
STEP
Standard ACK (NO/NC)
FUNCTION
OUTPUT RELAY SETUP
STEP
Relay Config. - Module 1 (up to 8)
STEP
Enter Relay Designation
STEP
Select Relay Type (Standard [NO/NC]/Pump Control Output [Select Tank (None/Tank #)]/
Momentary [NO/NC]/Pump Comm Control [Select Tank (None/Tank #)])
STEP
Relay Assignments - for each relay except Pump Comm Control types (In-Tank Alarms [None/
All /Single]/ Liquid Sensor Alarms [None/All /Single]/ Vapor Sensor Alarms [None/All /Single]]/
External Inputs [None/All /Single]]/ Line Leak Alarms - VLLD [None/All /Single]/ Groundwater
Alarms [None/All /Single]/ 2-Wire CL (Type A) Alarms [None/All /Single]/ 3-Wire CL (Type B)
Alarms [None/All /Single]/ Power Side DIM Alarms [None/All /Single]/ Reconciliation Alarms
[None/All /Single]/ PLLD Alarms [None/All /Single]/ WPLLD Alarms [None/All /Single]/ Comm
Side DIM Alarms [None/All /Single]/ Pump Relay Monitor Alarms [None/All /Single]
FUNCTION
PLLD LINE DISABLE SETUP
STEP
Relay Assignments - for each relay except Pump Comm Control types (In-Tank Alarms [None/
All /Single]/ Liquid Sensor Alarms [None/All /Single]/ Vapor Sensor Alarms [None/All /Single]]/
External Inputs [None/All /Single]]/ Line Leak Alarms - VLLD [None/All /Single]/ Groundwater
Alarms [None/All /Single]/ 2-Wire CL (Type A) Alarms [None/All /Single]/ 3-Wire CL (Type B)
Alarms [None/All /Single]/ Power Side DIM Alarms [None/All /Single]/ Reconciliation Alarms
[None/All /Single]/ PLLD Alarms [None/All /Single]/ WPLLD Alarms [None/All /Single]/ Comm
Side DIM Alarms [None/All /Single]/ Pump Relay Monitor Alarms [None/All /Single]
FUNCTION
WPLLD LINE DISABLE SETUP
STEP
Relay Assignments - for each relay except Pump Comm Control types (In-Tank Alarms [None/
All /Single]/ Liquid Sensor Alarms [None/All /Single]/ Vapor Sensor Alarms [None/All /Single]]/
External Inputs [None/All /Single]]/ Line Leak Alarms - VLLD [None/All /Single]/ Groundwater
Alarms [None/All /Single]/ 2-Wire CL (Type A) Alarms [None/All /Single]/ 3-Wire CL (Type B)
Alarms [None/All /Single]/ Power Side DIM Alarms [None/All /Single]/ Reconciliation Alarms
[None/All /Single]/ PLLD Alarms [None/All /Single]/ WPLLD Alarms [None/All /Single]/ Comm
Side DIM Alarms [None/All /Single]/ Pump Relay Monitor Alarms [None/All /Single]