5-3
Valco Cincinnati, Inc.
Section 5 - Operation
MC091 - VCX OT-120 FlexosealPro 2 - Corrugated
The Main Menu Screen - Continued
Name
Use
Product Counter Button
Print and reset the product counter by shift and by job.
Good Products/Job
Displays the number of good products for the job.
Bad Products/Job
Displays the number of bad products for the job.
Machine Speed (Products/Hour) Displays the number of products done per hour.
Machine Speed
(Meters or Feet/Minute)
Displays the speed of the machine in meters or feet per minute.
Current Glue Mode (picture)
The picture of the box with a glue mode pattern shows the current glue
mode. To change the glue mode, press on an unmarked area of the box.
Delay After Glue Line
Length of the area without glue after the glue valve fires.
Glue Line Length Length of the glue (length the glue valve fires).
Delay Before Glue Line
Length of the area without glue before the valve fires.
Carton ‘Score-to-Score’ Length Length of the area between ‘scores’ for carton folding.
Valve Setup Button
Setup glue valve information. Displays the current glue valve selected as
a number value under the picture of the valve.
Valve Number Displays current glue valve selected.
General Setup Button
Setup system parameters. Password protected levels define access
permissions.
Inspection Sensor Setup Button
Setup inspection tolerances, such as glue volume and glue position.
Encoder Setup Button
Setup the encoder pulse information and values associated with product
lengths.
Jam Detection Setup Button
Setup parameters for detecting carton jams.
Pressure Setup Button
Setup the purge pressure; enter the glue curve values based on
minimum encoder speed associated with minimum pressure and
maximum encoder speed associated with maximum pressure.
Tipsealer Status (if Tipsealer is
used)
NOTE: The Tipsealer Icon is not
shown in Figure 5-4.
Only available with Non-Contact
Glue Station.
Displays current Tipsealer position, by number:
Disabled
=
0 (No icon)
Valve On Parked
=
1
Valve On Gluing
=
2
Valve Off Parked
=
3
Valve Manual
=
4
Valve On Countdown
=
5
Current Pressure
Displays the current glue pressure in percentage.
Current Time and Date
Displays the current day and time.
Exit Button
Power Down (Exit) the Flexoseal PRO system. Confirmation is
necessary after pressing this button.