3-12
Valco Cincinnati, Inc.
Section 3 - Basic Features
MC091 - VCX OT-120 FlexosealPro 2 - Corrugated
Inspection Control Module (ICM) -
Continued
Inspection Control Module Features
Status LEDs:
Number
Name/Description
1
Sensor Power Supply LED
2
Marking Valve Power Supply LED
CAN –S - Illuminates steady green when two-way
communication is occurring. Flashes green when the
communication channel is open but a signal is not being
received at the present time.
3
CAN –E - Illuminates green when there is an error with
communication.
4
Good Product Detected (1-4)
5
Bad Product Detected (1-4)
6
Glue Level Sensor (1-4)
7 Trigger
(1-4)
8
Marking Valve (1-2)
9 Encoder
(1-2)
Inspection Control Module Features
Connectors:
Number
Name
10 RS-232
Port
11
Sensor Connection (1-4)
12
Marking Valve Connection
13
Sensor Connection (1-2)
14
Sensor Connection (3-4)
Inspection Control Module Features
Fuses:
Number Fuse
Type
Part No.
15a
Fuse Power Supply - Sensors (F1)
3.15A 085xx208
15b
Fuse Power Supply - Marking Valve (F2)
3.15A 085xx208