6-6
Valco Cincinnati, Inc.
Section 6 - Customize the Settings
MC091 - VCX OT-120 FlexosealPro 2 - Corrugated
Learn Volume
Procedure
To make the FlexosealPRO System learn the glue volume, first make sure
the glue line the system is producing on the product is satisfactory, and then
do the following:
1.
On the Main Menu Screen, press the Inspection Sensor Setup
Button. The Inspection Sensor Configuration Screen appears.
2.
On the Inspection Sensor Configuration Screen, make sure the
Volume Inspection switch is “ON” and the Inspection Sensor
Switch is “ON.”
Figure 6-9. Main Menu Screen
The recommended default
setting for the Volume
Inspector Switch is OFF.
Turn it ON only when
performing the system
Learn Glue Volume
procedure.
Figure 6-10. Inspection Sensor Configuration Screen
Inspection Sensor
Switch is ON
Volume
Inspection
Switch is ON
Inspection Sensor
Button