4-17
Valco Cincinnati, Inc.
Section 4 - Setup
MC091 - VCX OT-120 FlexosealPro 2 - Corrugated
Initialization Files Definitions
Device-Specific Profile Area
Index
(Hex)
Sub-Index
(Hex)
Name
Object
Type
Data
Type
Access
Type
Comment
Default Min
Max
3100
Parameter Valve Common
RECORD
Valve Common
0
Number of Entries
VAR
U8
RO
Largest supported Sub-index
11
1
TipSealer Enable
VAR
U16
RW
0=Disabled, 1=Enabled
0
0
1
2
TipSealer T1
VAR
U16
RW
TipSealer Time 1 in [ms]
500
100
2000
3
TipSealer T2
VAR
U16
RW
TipSealer Time 2 in [ms]
500
100
2000
4
TipSealer T3
VAR
U16
RW
TipSealer Time 3 in [ms]
500
100
2000
5
TipSealer T4
VAR
U16
RW
TipSealer Time 4 in [ms]
500
100
2000
6
TipSealer Feed Timeout
VAR
U16
RW
Timeout after Feedstop in [sec]
15
5
60
7
TipSealer Feed Polarity
VAR
U16
RW
Polarity of Feedstop Signal
0
0
1
8
TipSealer Pos.Switch Enable
VAR
U16
RW
Position Switch Enabled
1
0
1
9
Copied Valve Defaults
VAR
U16
RW
0=Valve Default Parameters
will be copied on next power
on
1=No action
0 0
1
A
Pulse Purge Activation
VAR
U16
RW
Number of Pulses at beginning
of purge cycle
0 0
50
B
TipSealer Status
VAR
U16
RO
TipSealer Status
0
0
255
C
Tipsealer Output Manual
VAR
U16
RW
This output is active when the
control is in the MANUAL
mode.
0 = No Output
1 = Glue Fault Light (Blue)
2 = Jam Fault Light (Red)
3 = Buzzer
4 = Low Level Light (Amber)
5 = Relay 1
6 = Relay 2
0 0
6
D
Tipsealer Output Error
VAR
U16
RW
This output is active when the
control is in the MANUAL
mode.
0 = No Output
1 = Glue Fault Light (Blue)
2 = Jam Fault Light (Red)
3 = Buzzer
4 = Low Level Light (Amber)
5 = Relay 1
6 = Relay 2
0 0
6
E
VAR
U16
RW
Glue Station Type.
0 = Not Installed
1 = Boardrunner NC-3
2 = Boardrunner NC-4
3 = Boardrunner NC-Hybrid
4 = Boardrunner Contact
Single
5 = Boardrunner Contact Dual
6 = BoardRunner FLP-3
7 = BoardRunner FLP-4
8 = Separated Valve NC
1 0
8
10
VAR
U16
RW
Cycle number when the valves
will switch to Jogg mode, after
a restart.
0 0
25
11
VAR U16 RW
Valve
Orientation
0 = Top Down
1 = Bottom Up
0 0
1