6-4
Valco Cincinnati, Inc.
Section 6 - Customize the Settings
MC091 - VCX OT-120 FlexosealPro 2 - Corrugated
Inspection Sensor Tolerance
Setup - Continued
Figure 6-6. Tolerance Setup Screen
3.
On the Tolerance Setup Screen, you can define the tolerances
for the 3 different levels (small, medium, and large)--each level
has an individual setting. You can set the tolerances for the glue
line start, the glue line end, the gaps between the glue lines, and
the volume. Just press on a tolerance value, and a keypad will
appear.
4.
When the keypad appears, enter the desired value and press
the keypad Confirmation Button. Continue this same process with
each value until all changes are made.
Confirmation Button
Cancel Button
Confirmation
Button
Start Tolerance
End Tolerance
Gap Tolerance
Tolerance Level
‘Large’
All tolerance values are in mm;
press for keypad
Tolerance Level
‘Small’
Tolerance Level
‘Medium’
Volume Tolerance
Not active at
this time
Figure 6-7. Keypad