7
vacon • 75
Technical data
Table 35. VACON
®
20 Cold Plate technical data.
Standards
Immunity
EN61800-3: 2004 + A1: 2011, 1
st
and 2
nd
envi-
ronment
Emissions
EN61800-3: 2004 + A1: 2011,
3-phase version
Category C2 as standard for
conducted and radiated
emissions
1-phase version
Category C1 as standard for
conducted emissions
Category C2 as standard for
radiated emissions. It can be
C1 with a suitable enclosure
and cabling.
The drive can be modified to category C4.
Safety
EN 61800-5-1
Production quality
ISO 9001
Approvals
Functional Safety
TÜV - Tested
Electrical Safety
TÜV - Tested
EMC
TÜV - Tested
USA, Canada
cURus approval, file number E171278
Declaration of
Conformity
Korea
KC mark
Australia
C-tick Declaration of Conformity
Europe
EC Declaration of Conformity
Protections
Undervoltage trip limit
Depends on supply voltage (0,8775*supply volt-
age):
Supply voltage 400 V: Trip limit
351 V
Supply voltage 480 V: Trip limit
421 V
Supply voltage 240 V: Trip limit
211 V
Earth fault protection
Yes
Mains supervision
Yes
Motor phase supervision Yes (not available in 1-phase version)
Overcurrent protection Yes
Unit overtemperature
protection
Yes
Motor overload protec-
tion
Yes
Motor stall protection
Yes
Motor underload
protection
Yes
Short-circuit protec-
tion of +24V and +10V
reference voltages
Yes
Thermal motor protec-
tion
Yes (by PTC with option card)
Summary of Contents for 20 CP
Page 1: ...vacon 20 cp ac drives installation Technical and Maintenance manual ...
Page 2: ......
Page 6: ...vacon 3 ...
Page 16: ...1 vacon 13 Safety Figure 6 STO certificate ...
Page 18: ...1 vacon 15 Safety ...
Page 24: ...vacon 21 Receipt of delivery 2 ...
Page 36: ...3 vacon 33 Mounting ...
Page 48: ...4 vacon 45 Power cabling ...
Page 64: ...5 vacon 61 Control unit ...