5.1.6
Led handling
As VACON
®
20 Cold plate is often without the keypad, on the plastic cover of the drive there are
4 status LEDs. See the picture below.
Figure 31. LED position on the MS2 cover.
Led “PWR” (orange led) means the drive is supplied by mains.
Led “RUN” (green led) means the drive is running.
Led “FLT” (red led) means the drive is experiencing a fault.
Led “RDY” (orange led) means the drive is ready and no fault is present. When a Warning is ac-
tive, the led starts blinking.