![Utax cd 1116 Service Manual Download Page 94](http://html.mh-extra.com/html/utax/cd-1116/cd-1116_service-manual_1064816094.webp)
Maintenance
Description
item No.
2DA/2DB
1-4-26
U099
Checking the original size detection
Description
Checks the operation of the original size detection sensor and sets the sensing threshold value.
Purpose
To adjust the sensitiveness of the sensor and size judgement time if the original size detection sensor
malfunctions frequently due to incident light or the like.
Start
1. Press the start key. The screen for selecting an item is displayed.
2. Select an item using the up/down cursor keys.
3. Press the start key. The screen for executing each item is displayed.
Display
Description
DATA
Displaying detection sensor transmission data
B/W LEVEL
Setting detection sensor threshold value
Setting original size judgment time
Method to display the data for the sensor
1. Press the start key. The detection sensor transmission data is displayed.
: 123 123 123
: 123 123 123
: 255 255 255
Rear of machine
Center of machine
Front of machine
Figure 1-4-5
2. To return to the screen for selecting an item, press the stop/clear key.
Setting
1. Select an item to be set using the up/down cursor keys.
Display
Description
Setting range
Initial setting
LEVEL
Detection sensor threshold value
0 to 255
170
WAIT TIME
Original size judgment time*
0 to 100
30
A4R AREA
Threshold value in the main scan direction
220 (mm)/
240
for A4R detection
240 (mm)
ORG AREA
Original size detection position display (mm)
0 to 350
–
SIZE
Detected original size display
0 to 63
–
* Time from activation of the original detection switch (ODSW) to original size judgment
Method to set the detection threshold value
1. Adjust the preset value using the left/right cursor keys.
A larger value increases the sensor sensitivity, and a smaller value decreases it.
2. Press the start key. The value is set.
3. To return to the screen for selecting an item, press the stop/clear key.
Method to set the original size judgment time
1. Adjust the preset value using the left/right cursor keys.
A larger value increases the original size judgment time, and a smaller value decreases it.
2. Press the start key. The value is set.
3. To return to the screen for selecting an item, press the stop/clear key.
Completion
Press the stop/clear key at the screen for selecting an item. The screen for maintenance item No. is displayed.
Summary of Contents for cd 1116
Page 1: ...Service Manual Copy CD 1116 CD 1120 Rev 1 ...
Page 2: ...Service Manual Copy DC 2116 DC 2120 Rev 1 ...
Page 4: ...This page is intentionally left blank ...
Page 247: ...2DA 2DB 1 2 3 2 Figure 2 3 2 Power source PCB silk screen diagram 220 240 V AC 120 V AC ...
Page 264: ...2DA 2DB 1 2 3 19 Figure 2 3 10 Operation unit PCB silk screen diagram ...