(9) Adjusting the scanner center line
Perform the following adjustment if there is a regular error between the center lines of the copy image and original.
U034
(P. 1-6-18)
U072
(P. 1-4-18)
U067
Caution:
Before making the following adjustment, ensure that the above adjustments have been made in maintenance mode.
Procedure
Yes
No
Start
Enter maintenance mode.
Enter “067” using the numeric keys.
Press the start key.
Press the interrupt key.
Place an original and press
the start key to make a test copy.
Select the items to be adjusted
using the up/down cursor keys.
Is the scanner
center line correct?
Press the start key.
The new setting
is stored.
Setting range (Initial setting)
ADJUST DATA 1: –39 – +39 (–4)
ADJUST DATA 2: –39 – +39 (0)
Changing the value by 1 moves
the center line
ADJUST DATA 1: 0.17 mm
ADJUST DATA 2: 0.084 mm
For copy example 1, decrease
the value using the left cursor key.
For copy example 2, increase
the value using the right cursor key.
Press the stop/clear key to
exit maintenance mode.
End
ADJUST DATA 1:
ADJUST DATA 2:
Original
Copy
example 1
Copy
example 2
Scanner center line
Figure 1-6-67
Summary of Contents for cd 1116
Page 1: ...Service Manual Copy CD 1116 CD 1120 Rev 1 ...
Page 2: ...Service Manual Copy DC 2116 DC 2120 Rev 1 ...
Page 4: ...This page is intentionally left blank ...
Page 247: ...2DA 2DB 1 2 3 2 Figure 2 3 2 Power source PCB silk screen diagram 220 240 V AC 120 V AC ...
Page 264: ...2DA 2DB 1 2 3 19 Figure 2 3 10 Operation unit PCB silk screen diagram ...