![Utax cd 1116 Service Manual Download Page 237](http://html.mh-extra.com/html/utax/cd-1116/cd-1116_service-manual_1064816237.webp)
2DA/2DB-1
2-1-16
Temperature
(
°
C)
Preset temperature (
°
C)
(secondary stabilization)
Fixing heater S (FH-S)
Fixing heater M (FH-M)
HEAT signal
HEAT signal
Time
500 ms
On
On
On
On
On
On
Off
Off
Off
Off
Warm-up
control
Ready state
control
(1) Fixing temperature system
Figure 2-1-19 Fixing temperature system
• Warm-up control
1. 500 ms after the fixing heater S (FH-S) turns on, the fixing heater M (FH-M) turns on.
2. When the fixing temperature reaches preset temperature, both fixing heater S (FH-S) and fixing heater M (FH-M) turn off
simultaneously.
• Ready state control
1. When the fixing temperature drops to the preset temperature, fixing heater S (FH-S) turns on, and after specified time, the
heater turns off.
2. When fixing heater S (FH-S) turns off, fixing heater M (FH-M) turns on at the same time, and after specified time, the heater
turns off.
3. The operation above is repeated to keep the fixing temperature to the preset temperature.
* If a temperature more than or equal to the preset tempe 20°C/68°F is detected, both fixing heater S (FH-S) and
fixing heater M (FH-M) are turned off forcibly.
(2) Fixing temperature control based on ambient temperature
This machine performs fixing temperature control based on the ambient temperature.
Ambient temperature
Lower than 13
°
C/55.4
°
F
Higher than or equal to 13
°
C/55.4
°
F,
lower than 18
°
C/64.4
°
F
Higher than or equal to 18
°
C/64.4
°
F,
lower than 31
°
C/87.8
°
F
Higher than 31
°
C/87.8
°
F
Fixing temperature (
°
C)
Reference value +10
Reference value +5
Reference value
Reference value -5
Summary of Contents for cd 1116
Page 1: ...Service Manual Copy CD 1116 CD 1120 Rev 1 ...
Page 2: ...Service Manual Copy DC 2116 DC 2120 Rev 1 ...
Page 4: ...This page is intentionally left blank ...
Page 247: ...2DA 2DB 1 2 3 2 Figure 2 3 2 Power source PCB silk screen diagram 220 240 V AC 120 V AC ...
Page 264: ...2DA 2DB 1 2 3 19 Figure 2 3 10 Operation unit PCB silk screen diagram ...