PLS4.75
PLS6.75
PLS6MW
(multi wavelength)
PLS6.150D
Operating
Environment
Well-ventilated office (recommended) or clean, light-duty manufacturing
Operating
Temperature
50ºF (10ºC) to 95ºF (35º C) capable
73ºF (22ºC) to 77ºF (25º C) for best performance
Storage Temperature
50ºF (10ºC) to 95ºF (35º C)
Operating Humidity
Non-condensing
Particulate/Odor
Outside Ventilated
Exhaust System
High-pressure vacuum blower capable of:
250 CFM (cubic feet per minute) @ 6 inches
static pressure (425m3/hr at 1.5kPa)
500 CFM (cubic feet per minute) @ 6 inches static
pressure (850m3/hr at 1.5kPa)
Computer
Requirements
(See the Installation & Set-up
Guide for more information)
Windows XP, Windows Vista, or Windows 7 (32 and 64 bit)
2.0 GHz Processor (minimum)
1 GB of RAM (minimum)
40 GB Hard Drive (minimum)
Software
Requirement
Graphics or CAD based (See page 61 for recommendations)
Laser Safety
Main Laser, Interlocked Safety Enclosure = Class 1
Red Diode Pointer = Class 2
6
Summary of Contents for PLS4.75
Page 1: ...PLS User Guide PLS4 75 PLS6 75 PLS6 150D PLS6MW www ulsinc com Revision August 2012...
Page 5: ...Chapter 1 Specifications 5...
Page 8: ...Chapter 2 Safety 8...
Page 14: ...Tamper Proof Labels Safety Labels...
Page 15: ...ULS Fiber Laser Cartridge Labels 15...
Page 16: ......
Page 17: ...PLS4 Back View 17...
Page 18: ...PLS6 Front View 18...
Page 19: ......
Page 22: ...Chapter 3 Installation 22...
Page 40: ......
Page 48: ...Chapter 4 Operation 48...
Page 83: ...Chapter 5 Accessories 83...
Page 99: ...Example Connection for PNP mode Example Connection for NPN mode 99...
Page 111: ...Chapter 6 Maintenance 111...
Page 119: ...www ulsinc com...