![United Technologies Carrier Weathermaker 48A2 Controls, Start-Up, Operation, Service, And Troubleshooting Download Page 155](http://html1.mh-extra.com/html/united-technologies/carrier-weathermaker-48a2/carrier-weathermaker-48a2_controls-start-up-operation-service-and-troubleshooting_4065174155.webp)
155
APPENDIX B — CCN TABLES (cont)
STATUS DISPLAY TABLES (cont)
TABLE
DISPLAY NAME
RANGE
UNITS
POINT NAME
WRITE STATUS
TEMPCTRL
Evaporator Discharge Tmp
dF
EDT
Leaving Air Temperature
dF
LAT
Mixed Air Temperature
dF
MAT
Controlling Return Temp
dF
RETURN_T
forcible
Controlling Space Temp
dF
SPACE_T
forcible
TEMPS
Air Temp Lvg Supply Fan
dF
SAT
Return Air Temperature
dF
RAT
forcible
Outside Air Temperature
dF
OAT
forcible
Space Temperature
dF
SPT
forcible
Space Temperature Offset
^F
SPTO
forcible
Staged Gas LAT Sum
dF
LAT_SGAS
Staged Gas LAT 1
dF
LAT1SGAS
Staged Gas LAT 2
dF
LAT2SGAS
Staged Gas LAT 3
dF
LAT23SGAS
Staged Gas Limit Sw.Temp
dF
LIMSWTMP
Cir A Sat.Condensing Tmp
dF
SCTA
Cir B Sat.Condensing Tmp
dF
SCTB
Cir A Sat.Suction Temp.
dF
SSTA
Cir B Sat.Suction Temp.
dF
SSTB
DS Discharge Temperature
dF
DTDS
TSTAT
Control Mode………..:
ascii text strings
Thermostat Y1 Input
On/Off
Y1
forcible
Thermostat Y2 Input
On/Off
Y2
forcible
Thermostat W1 Input
On/Off
W1
forcible
Thermostat W2 Input
On/Off
W2
forcible
Thermostat G Input
On/Off
G
forcible
UINPUTS
Filter Status Input
Dirty/Clean
FLTS
forcible
Fan request from IGC
On/Off
IGCFAN
Fire Shutdown Switch
Alarm/Normal
FSD
forcible
Thermostat G Input
On/Off
G
forcible
Thermostat W2 Input
On/Off
W2
forcible
Thermostat W1 Input
On/Off
W1
forcible
Thermostat Y2 Input
On/Off
Y2
forcible
Thermostat Y1 Input
On/Off
Y1
forcible
Economizer Control Input
On/Off
ECOSW
forcible
Remote Economizer Enable
Yes/No
ECONENBL
forcible
Econo Position Override
Yes/No
ECOORIDE
forcible
Remote Input State
On/Off
RMTIN
forcible
Supply Fan Status Switch
On/Off
SFS
forcible
Demand Limit Switch 1
On/Off
DMD_SW1
forcible
Demand Limit Switch 2
On/Off
DMD_SW2
forcible
Pressurization Input
Alarm/Normal
PRES
forcible
Evacuation Input
Alarm/Normal
EVAC
forcible
Smoke Purge Input
Alarm/Normal
PURG
forcible
IAQ - Discrete Input
High/Low
IAQIN
forcible
Dehumidify Switch Input
On/Off
DHDISCIN
forcible
Summary of Contents for Carrier Weathermaker 48A2
Page 105: ...105 Fig 20 Typical Main Control Box Wiring Schematic 48 50A2 A3 A4 A5 Units...
Page 106: ...106 Fig 21 Typical Auxiliary Control Box Wiring Schematic...
Page 107: ...107 Fig 22 Typical 2 Stage Gas Heat Wiring Schematic Size 060 Units Shown a48 8357...
Page 108: ...108 TO NEXT PAGE Fig 23 Typical Staged Gas Heat Wiring Schematic Size 060 Units Shown A48 7296...
Page 109: ...109 Fig 23 Typical Staged Gas Heat Wiring Schematic Size 060 Units Shown cont A48 8358...
Page 110: ...110 Fig 24 Typical Electric Heat Control Schematic 50 Series Size 060 Units Shown a50 8228...
Page 111: ...111 Fig 25 Typical Power Schematic 48 50A2 A3 A4 A5 060 Unit Shown...
Page 112: ...112 Fig 26 Typical Low Ambient Controls Option Wiring...
Page 113: ...113 Fig 27 Typical Small Chassis Component Location Size 020 035 Units...
Page 114: ...114 Fig 28 Typical Large Chassis Component Locations Size 040 060 Units...
Page 118: ...118 Fig 30 Economizer Control Board ECB1 and VAV Control Board ECB2 A48 7706...
Page 142: ...142 A48 3733 Fig 56 Main Burner Removal...
Page 176: ...176 APPENDIX C VFD INFORMATION cont Fig F Internal Enclosure Fan Replacement A48 7716...