Chapter
5
5-11.
Control Input Select
Select the method for specifying the control (SECTION signal, T/H signal, or START/STOP
signal) input.
COM.:
Control by external input becomes ineffective, and only control by
communication becomes effective.
EXT.:
Control by communication becomes ineffective, and only control by
external input becomes effective.
How to set
5-12.
B6 OFF Detect Wait
In hold controlled by the T/H signal alone, detection/hold section is assured during the set waiting
time. This is convenient for ignoring chattering parts.
≪
Setting value
≫
0.00 to 1.00 [sec.]
Example) Sample hold
How to set
5-13.
B8 OFF Detect Wait
This is convenient in hold controlled by the SECTION signal.
Operationally, detection/hold section is assured as in the case of B6 OFF detection wait.
The timer functions so as to also ignore chattering when the OFF edge is detected.
≪
Setting value
≫
0.00 to 1.00 [sec.]
How to set
SET.
Operation
Page 3
→
→
System Setting
→
Hold point displaced due
Hold point to be taken under
Hold section
t
+
T/H
Tracking section
Tracking section
to chattering
Chattering
(80msec)
Chattering operation is ignored
Hold section
t
+
Tracking section
because the input is not recognized.
0.10-sec.
assured section
Tracking section
⇒
When the waiting time is 0.00 sec.
When the waiting time is 0.10 sec.
ON
OFF
T/H
ON
OFF
normal circumstances
SET.
Operation
Page 3
→
→
System Setting
→
SET.
Operation
Page 3
→
→
System Setting
→