58
5
SETTING OF FUNCTIONS
58
SE
TT
IN
G
O
F F
U
N
C
TIO
N
S
Chapter
5
2. Normal [setting value writing/reading]
Reading the indicated value/status
Function
Header
Protocol
Main
Sub
Wave form
hold point data
read-out
R
X
Setting value writing
Function
Header
Protocol
Main
Sub
Various
settings
W
-
R
,
5
2
0
X
R
CR
X
Host
TM700
Data 0000 to 1999
0 1
3 4 5 6
0
2
0
6
0
0
+
.
0
Rotation speed (Sign (fixation), 5-digit, decimal place)
,
15 16 17 18 19 20
22
21
2
.
6
0
+
3
8
Power (Sign, 5-digit, decimal place)
23 24 25 26 27 28 29
Delimiter
.
0
0
1
+
0
0
Torque (Sign, 5-digit, decimal place)
,
7 8 9 10 11 12
14
13
Data section No. for waveform data reading
One graph plotting screen includes 2000 pieces of data. In reading waveform
data, data can be read by being divided into 200 sections (by 10 pieces).
Section 000
Data 0000 to Data 0009
Section 001
Data 0010 to Data 0019
Section 099
Data 1990 to Data 1999
~
~
Point
W
CR
Host
TM700
Setting value (Sign, 5-digit, no decimal place)
Command
(For a setting value with a decimal place, simply write
the numerical value excluding the decimal place.)
W
CR
* When the number of digits of the setting value is smaller than five,
Example) 3 digits
* *
+ 0 0 1 2 3
W
CR
* When the setting value is unsigned, put a zero in the sign digit.
* *
0 0 0 0 0 3
put a zero in the higher digit(s).