54
5
SETTING OF FUNCTIONS
54
SE
TT
IN
G
O
F F
U
N
C
TIO
N
S
Chapter
5
■
USB interface setting
Set the USB communication conditions of the TM700.
Communication mode
≪
Setting value
≫
Normal:
This mode performs communication by a command from the host computer.
In this mode, you can read out the indicated value, status, set values and write in set values.
* Please be sure to use this setting in the case of use of the TM700 PC application software.
Cont. 1:
This mode continuously transmits the indicated values and the status.
Indicated value and status are synchronized with hold.
Print:
When the indicated value is printed (a print command is output to the SI/F),
the indicated value and status are sent from the TM700 to host.
Cont. 2:
This mode continuously transmits the indicated values and the status.
Only indicated value is not synchronized with hold.
How to set
Baudrate
≪
Setting value
≫
9600, 19200, 38400, 57600, 115.2k, 230.4k [bps]
How to set
Data bit
≪
Setting value
≫
7bit, 8bit
How to set
Stop bit
≪
Setting value
≫
1bit, 2bit
How to set
Parity bit
≪
Setting value
≫
NONE, EVEN, ODD
How to set
Delimiter
≪
Setting value
≫
CR, CR
+
LF
How to set
SET.
USB Setting
Page 1
→
→
System Setting
→
SET.
USB Setting
Page 1
→
→
System Setting
→
SET.
USB Setting
Page 1
→
→
System Setting
→
SET.
USB Setting
Page 1
→
→
System Setting
→
SET.
USB Setting
Page 1
→
→
System Setting
→
SET.
USB Setting
Page 1
→
→
System Setting
→
Summary of Contents for TM700
Page 1: ...20MAY2021REV 1 08 TORQUE MONITOR TM700 OPERATION MANUAL ...
Page 91: ......