Chapter
5
5-17.
RUN Output Select
External output "RUN" stops when abnormal state of indicated value is detected.
The conditions of stopping the output caused by abnormal state are as follows.
-
±
LOAD (Sensor error)
- OFL (Overflow error)
- ALM HI/LO (Alarm HI/LO limits)
- cErr (Calibration error)
- DZ Err (Digital zero limit error)
≪
Setting value
≫
Toggle, ON Level, OFF Level
How to set
RUN out specifications are as follows.
RUN output spec.
- Toggled ON-OFF
- Fixed ON level
- Fixed OFF level
The ON-OFF relationship is the inverse of the fixed ON level case.
See to "Error Display List" on page 71
about the contents of errors.
SET.
Operation
Page 3
→
→
System Setting
→
CAUTION
Be aware that judgment is difficult if a hardware error occurs (if the level is fixed for
some reason) when the output is fixed.
RUN
OFF
ON
500msec pulse
This signal turns off when an error occurs.
duty approx.50%
RUN
OFF
ON
By the error factor removal,
3.0sec
Error factor removal
ON-OFF operation restarts in 3.0sec.
RUN
OFF
ON
3.0sec
OFF
ON
Error factor removal
Turns ON in 3.0 sec.
This signal turns off when an error occurs.
by the error factor removal.
RUN