Sageon III Power System
Introduction
PM990-8800-00, Rev. 9
1-9
1.4 REFERENCE PUBLICATIONS
DOCUMENT
NUMBER
TITLE
ANSI C 39.1
Requirements for Electrical Analog Indicating Instruments
ANSI T1.311-1991
DC Power Systems - Telecommunications Environment Protection
ANSI/IEEE C 62.41-
1980
IEEE Guide for Surge Voltages in Low-Voltage AC Power Circuits, ANSI
IEC 801-2
IEC Electromagnetic Compatibility for Industrial-Process Measurement and
Control Equipment, October 1987
NEC 1993
NEC Handbook 1993, National Fire Protection Association
No Number
OI-28 Standards
No Number
Central Office Telecommunications Equipment Engineering Standards,
December 1984
PUB 77350
U S West Telecommunications Equipment Installation & Removal Guidelines,
May 1990
PE-7-1985
Communications Type Battery Chargers, NEMA/ANSI
STD 487-1980
IEEE Guide For The Protection of Wire-Line Communications Facilities
Serving Electrical Power Stations
TR-EOP-000151
Bellcore Generic Requirements for 24-, 48-, 130-, & 140-Volt Central Office
Power system Rectifiers, May 1985
TR-EOP-000154
Bellcore Generic Requirements for 24-, 48-, 130-, & 140-Volt Central Office
Power system Control and Distribution, May 1985
TR-NWT-000063
Bellcore Network Equipment-Building System Generic Equipment
Requirements, Issue 4, July 1991
TR-TSY-000078
Bellcore Generic Physical Design Requirements for Telecommunication
Products and Equipment
UL489
UL Molded Case Circuit Breaker Enclosures, May 1984
Monitoring Specifications
Operator panel voltage and current ............... 2-line digital display
Operator panel accuracy
Voltage accuracy ................................... 0.50% +/- least significant digit
Current accuracy .................................... 1%
System status................................................. Green, yellow, and red LEDs
Local Communications ................................. USB (SageView required)
Remote Communications .............................. Ethernet/SNMP
Alarm Specifications
Each of following alarms is annunciated by a lighted LED on the operator panel and by a relay state change. Relay contact output
terminals are on the alarm PCB in the distribution.
A. User Alarm Annunciation
Five user programmable relays. One form C contacts rated 1A resistive @ 24Vdc, 0.5A resistive @ 48Vdc.
B. Rectifier Front Panel
Three status LEDs (Green, Amber, and Red) are located on the Rectifier front panel.
C. Battery Current Temperature
Battery Temperature Sensor Input ................ Compensation and alarm annunciation, 1ambient, 1-4 battery
Battery Current Transducer Input ................. 1-4 battery strings; accuracy 1%
User connections ........................................... No. 6 screw terminals; lugless compression type
D. Sageon Battery Monitor
Battery strings ............................................... 4 maximum