205
Read Input Resolution
Read the reported resolution for an input.
Command
Slots.Slot1.In1.Set_Resolution
or
Slots.Slot1.In1.Measured_Resolution
(In this case, Slot 1 and In 1 are used as an example - any valid slot number and input
number can be used in that context.)
Description
Reads the currently detected resolution on an input.
Example
Slots.Slot1.In1.Set_Resolution
Slots.Slot1.In1.Set_Resolution = NewCustomResolution
!Done Slots.Slot1.In1.Set_Resolution
or
Slots.Slot1.In1.Measured_Resolution
Slots.Slot1.In1.Measured_Resolution = NewCustomResolution
!Done Slots.Slot1.In1.Measured_Resolution
Default
n/a - the behavior is to show the name of the detected resolution or nothing if no signal is
detected.
Notes
Set_Resolution
and
Measured_Resolution
are duplicate commands and produce
identical results.
If a Custom Resolution and a built-in resolution are both within the selection tolerance, the
Custom Resolution will be selected.
Custom Resolutions cannot be detected on an SDI input.