Section 5
Using the TROY Port Monitor
Security Printing Solutions User’s Guide -- 50-70410-002 Rev. A
5-8
Security Tab
(cont.)
Alternate Escape Sequence
– (used only for legacy application compatibility) enter the alternate ASCII character
number (0-255) to use as a replacement for the ASCII character 27 (escape character) in the PCL 5 data stream
sent to the printer. Press the
Alt
key and enter the ASCII character number.
Enable MICR Mode
– check this box to enable
MICR mode when printing MICR documents.
HP Job Password
– (used only for legacy
TROY printers) enter the password (0-65535)
that matches the job password (PJL command)
set in the TROY printer by the administrator.
Automatic Page Rotation
– when printing
checks with the MICR line at the bottom of the
check paper, check this box to rotate the page
image 180 degrees to print the MICR line at the
top of the page, ensuring accurate MICR line
placement.
TROYmark
™
– select
Disable
for no
background image on the check or select either
Light
,
Medium
, or
Dark
to use a pre-defined
density level for the background image, or
select
Custom
to use a custom density level that
best suits the design of your check.
Inclusion and Exclusion Regions
– enter the
appropriate “X” (horizontal) and “Y” (vertical)
offset numerical values to define the top-left
starting point of the inclusion region and the
exclusion region(s), and then enter the width
and height numerical values to define the
bottom-right ending point of the inclusion and
the exclusion region(s) for placement of the
TROYmark
™
background image and exclusion areas. Click on
Test
to print a sample page to verify the
inclusion/exclusion region placement on the check. Make adjustments to the numerical values as needed. Each
increment in the numeric value equals 1/600th of an inch.
TROYmark Background Image
(Inclusion rectangle)
Y value
Width Value
Check Document
Height Value
X value
exclusion
rectangle
Y value
X value