Program 05-24-IP : System Timing Parameters – 24
05-24-IP SYS PAR
0 0 0 0 0 0 0 0
IP = 01-08
System Default.
Item
Display
Programming Data
Timing
Pointer
Data
Description
Table
Default
---------- ----------
-----------------------------------------------------------
----------
------------
01
0-1
0=
02
0-1
0=
03
0-8
0=
04
0-8
LYNX Monitor System Tracking
0=Disable
05
0-9
0=
06
0-1
LYNX Monitor RS232 Output
0= Disable
07
0-1
LYNX Monitor DSP trace
0= Disable
08
0-3
LYNX Monitor VMC Trace
0= Disable
Description:
01. Reserved:
02.Reserved:
03. Reserved:
04. LYNX Monitor System Tracking
This parameter enables the LYNX monitor system and handset tracking features.
0= Disable
2 = enable monitor Tx to DK phone trace
3 = enable monitor Tx to DK phone trace
4 = enable monitor SWITCH ACTION trace
5 = enable monitor SWITCH ACTION trace
6 = enable monitor SWITCH ACTION trace & monitor Tx to DK phone trace
7 = enable monitor Tx to DK phone trace &monitor SWITCH ACTION trace
05. Reserved:
06. LYNX Monitor Output:
This parameter enables/disables the LYNX monitor RS232 output
0 = disable output monitor to RS-232
1 = enable output monitor to RS-232