Installing the Equipment
Backboard
Be sure to plan and allow enough space to
mount and connect the key service unit, power
supply and system battery back up if applicable.
Key Service Unit
Use the enclosed paper template to locate the
mounting position for the Key Service Unit. Drill
appropriately spaced holes and mount the KSU
on the wall. When mounting the KSU, make certain that there is adequate room for the system power
supply and that the connecting cable between the Power Supply and the KSU will reach the KSU. The
same applies for the battery back up unit.
Power Supply
Dedicated Power Source - The power supply must be connected to a dedicated AC outlet.
Be sure that the third wire earth ground of the AC circuit is connected to a good electrical ground. If a
music source is installed, it must be connected to a separate AC circuit rather than the system's dedicated
AC line cord.
Check Your power adapter
Verify that the input voltage and power adapter input voltage are correct before you connect and power on
the system. The input voltage is set according to the Customer's requirement before shipping. However it
is important to verify that the setting is correct prior to initial system power up.
Power adapter supply voltage options for
the
unit:
100-VAC: 100 to 120 V AC (50/60Hz) or
240-
VAC: 205 to 265 V AC (50/60Hz).
Mount Power adapter
Using screws provided with the system,
mount
the power adapter close to the KSU so that
the
connector reaches from the Power Supply to
the
KSU.
Preparing The External Battery Backup
The Key Service Unit uses one external backup battery unit containing 2 x 12v batteries in series (24
volts) for emergency power when a power failure takes place.
If you are installing an optional Battery Backup (BBOX1), make certain that there is adequate room for its
installation. Make certain that the Battery Backup is mounted close enough to the Power Supply that the
interconnecting cable between the Battery Backup and the Power Supply can connect.
Do Not Connect the Battery Backup at this time!
Do Not Connect the Battery Backup at this time! Battery Backup should not
be connected to the System power supply until all power up testing has
been completed!
Wall or backboard
Key Service Unit
Mounting Tabs
Summary of Contents for Lynx DK6 Series
Page 1: ...Telephone System Master Programming Manual Rev 2 1c ...
Page 2: ......
Page 24: ...Page 24 ...
Page 34: ...Page34 ...
Page 40: ...Page40 ...
Page 44: ...Page44 DK6 Key Telephone Key Layout 18 Button DK7 Key Telephone Key Layout ...