LYNX Plus Programming Manual Rev 2.1c
Page
181
All prompts except the initial greeting message are already recorded on the MBU. The user should only
need to program Day, Night, Lunch Time, Holiday and extended greetings as required.
Programming Standard DISA
This assumes that you have followed the previous instructions to record DISA messages.
Set the timers in Mode 05-01-04 and 05-11-04, 05-17-04 to select answer time for Day, Night and Lunch
Set in mode 05-07-04 whether unsuccessful or no dial calls will revert to the operator or be disconnected.
Set in Mode 05-08-06 the time interval between retries when the call is attempting to connect to a station.
It is important that the DISA timer is set to longer than the Call forward no Answer timer or DISA calls may
not go to the VM when required.
Set in Mode 05-08-07 the time interval that is left for the customer to complete dialing after hearing the
greeting message.
If Polarity reversal or Clear Forward are used then set the appropriate mode to suit your network.
It is preferable to use DISA busy tone detect to clear down calls as no input is required from the Exchange
and no additional charges can be incurred.
If callers are to access an outside line after DISA answer then this must be enabled in Mode 05-11-05.
Calls through the system using this feature will be controlled by mode 05-06-06 which is a timer to make
certain that calls do clear down when 2 trunks are tied together. When a timer is set the parties to the call
will receive a tone just prior to the time elapsing and can send a DTMF digit to the system to extend the
call for another time period before again alerting the parties to the next timeout period.
Set Mode 05-11-06 to the number of retries that an unanswered call or a call to a busy station will make
before cutting the call. If supervision is available to clear down when the caller hangs up or DISA Busy
tone detect is used then this should be set to 9 which means that it will retry until the caller hangs up.
Mode 05-15-01 sets the date stamp setup whether it is US order or English order.
Mode 05-16-03/04 Enables / Disables dual language service and selects which digit to dial to access the
second language service after DISA answer.
If Callers are allowed to access an outside line then a password must be set in Mode 13-02