LYNX Plus Programming Manual Rev 2.1c
Page
145
Program (51 to 59)-code-IP : Toll Plans – Allowed Digits – Class 1 to 9
51-code-01 Allow
- - - - - - - - - - - - -
Code=Code No. (01-16), IP =
Item Pointer (01-12)
Value for the Item
General:
This program sets allowed exception numbers for Toll Class 1. These Modes should be read in
conjunction with Modes 61 to 66.
Description:
There are 16 codes for each Toll Class and each code contains up to 12 digits
In default any station allocated to Toll Plans 1 to 6 will be able to dial unrestricted until the associated
Modes are programmed.
Allowed entries in this Mode are 0 to 9, d and _. d = Don't care and means that any digit can be dialled in
this position. _ = No digit is allowed to be dialled beyond this position. If a digit is allowed as the beginning
of a number then the entry should be filled with don't care's to the end of the line or the caller will not be
able to dial the full number.
Modes 51 to 56 are used in conjunction with Modes 61 to 66 and Modes 57 to 59 are used independently.
Toll Classes:
Class
Function
Prog. Mode
0
Unrestricted
Default
1
Use Mode 51 for the Unrestricted numbers. Use Mode 61 for the Restricted numbers
Mode
51,61
2
Use Mode 52 for the Unrestricted numbers. Use Mode 62 for the Restricted numbers
Mode
52,62
3
Use Mode 53 for the Unrestricted numbers. Use Mode 63 for the Restricted numbers
Mode
53,63
4
Use Mode 54 for the Unrestricted numbers. Use Mode 64 for the Restricted numbers
Mode
54,64
5
Use Mode 55 for the Unrestricted numbers. Use Mode 65 for the Restricted numbers
Mode
55,65
6
Use Mode 56 for the Unrestricted numbers. Use Mode 66 for the Restricted numbers
Mode
56,66
7
Use Mode 57 for the Unrestricted numbers.
Mode
57
8
Use Mode 58 for the Unrestricted numbers.
Mode
58
9
Use Mode 59 for the Unrestricted numbers.
Mode
59
*
Use Mode 51-56 for unrestricted numbers. Use Mode 61-66 for all restricted numbers
000
D
Cannot access the trunk line.
Note 1:
Default numbers in Mode 61, 62, 63, 65, 66 are: dddddddd
Note 2:
Default numbers in Mode 51, 52, 53, 55, 56, 57, 58, 59 are:------------
Note 3:
d: Don't care: any digit is allowed in this position.
Note 4:
_: The system does not allow any digits dialled after this symbol.
Default : 59-01=000dddddddddd
Note:
Default Settings:
COS1 = Allow 0800 and 0508