Page
88
Program 05-18-IP : System Timing Parameters – 18
05-18-IP SYS PAR
0 0 0 0 0 0 8 5
IP =
Item Pointer (01-08)
Value for each Item
IP
Value
Default
Item Description
01 0-
0=
Reserved
02 0-
0=
Hotel Alarm
03 0-1
1=Enable
Dial out History Feature
04 0-
0=
Reserved
05 0-
0=
Reserved
06 0-
0=
Play Transfer message for ECF
07 0-9
8= -9db
High Frequency Level of DTMF Generator
08 0-9
5= -11.4db
Low Frequency Level of DTMF Generator
01. Reserved
02. Hotel Alarm
This feature is designed for the Hotel environment but also could be used in other situations.
When the user presses an emergency button that provides a short circuit on the pair of an SLT extension
line this will trigger an Alarm Ring signal to the console with the LCD message as follow:
If a user lifts the handset to make an emergency call, but can’t talk for some reason (usually health
related), after 2 minutes, the console will receive an Alarm Ring with the LCD message as follows:
IP \ Value
0
1
05-18-02 Disable this feature Enable this feature
Note:
Extension that need this feature should be enabled in mode: 50-STN-08: Hotel Alarm.
03. Dial Out History Feature
This parameter enables a dial out history memory buffer. When this feature is enabled the user can press
[Redial] and using the [Up/down] volume keys, scroll through the last 10 dialled out numbers and then
pressing the [SPK] key to dial out the numbers.
IP \ Value
0
1
05-18-03
Disable
Enable
Extension: xx
Shower Alarm
Extension: xx
Handset Alarm