Page
158
Program 83-st-IP : Register Memory Block for CLI history buffer
83-stn-IP CLI-T
b1 b2
Stn=Station No. (2-4 digits), IP =Item Pointer (01-02)
blocks (2 max.) for a Station
b1/b2
: Block 1/2 of CLI buffer for each extension
General:
This program divides sets of
CLI history buffer
into blocks for use by extensions.
Description:
Program
05-13-03,
the Individual CLI history buffers are assigned:
05-13-03
Memory Block Size
Max. Memory blocks
0
10 sets/Block
52 Blocks
1
20 sets/Block
26 Blocks
2
30 sets/Block
17 Blocks
3
40 sets/Block
13 Blocks
Each station can use up to 2 blocks.
The next assigned block must be null or continuous after the first assigned block number for each
extension. That means if the first assigned block number is “n” then the next assigned block must be
“0 = null” or “n+1”.
Example
:
Mode 05-13-03=0
83-
113
-IP CLI-T
01 02
13
: Station No. ( 2-4 digits )
01 02
: Station 113 can use block
01
and
02
for CLI history
buffer and it could store 20 sets (=10 + 10).
Mode 05-13-03=1
83-
115
-IP CLI-T
04 00
15
: Station No. ( 2-4 digits )
04 00
: Station 115 can use block
04
(20 sets) for CLI history
buffer.
00
: for no block.
Mode 05-13-03=3
83-118-IP CLI-T
03 00
18
: Station No. ( 2-4 digits )
03 00
: Station 118 can use block
03
for CLI history buffer and
it could store 40 sets,
00
: for no block.
Related System Programming Mode: 05-13-03, 83
Summary of Contents for Lynx DK6 Series
Page 1: ...Telephone System Master Programming Manual Rev 2 1c ...
Page 2: ......
Page 24: ...Page 24 ...
Page 34: ...Page34 ...
Page 40: ...Page40 ...
Page 44: ...Page44 DK6 Key Telephone Key Layout 18 Button DK7 Key Telephone Key Layout ...