Program *12 System Assignments, Basic Timing
System & Station
Strata DK40 Programming Manual Spring 1999
3-31
Program *12
System Assignments, Basic Timing
Program Type:
System
Initialised Default:
Program Timing
Code 1
3
Code 2
1
Code 7
2
Code 8
2
(QWHU 3URJ 0RGH
0
6SNU
*
4 5
+ROG
0
6SNU
0
0
+ROG
0
6SNU
& &
+ROG
0
6SNU
& &
+ROG
Program
Code
Function
Code
Time
Required
Code
1
Disconnect
Timer
(TIE Lines Only)
1
20 sec.
2
30 sec.
4
40 sec.
2
Delay Dialling
Timer
(TIE Lines Only)
1
0.2 sec.
2
0.8 sec.
3
1.6 sec.
7
Ring Time
on
DISA Lines
1
120 sec.
2
15 sec.
3
240 sec.
4
30 sec
8
Automatic Release
Timer
(TIE Lines Only)
1
No Automatic Release
2
30 mins.
3
60 mins.
SELECT = 1, 2, 7 or 8
Enter program code, 1, 2, 7 or 8 from table below.
SELECT CODE = Enter required code
for the time listed in the table below.